Choose by type, application, or function

Select by Type

Select by Input withstand voltage

Select by Frequency bandwidth

Select by Attenuation

Select by Application

Select by Manufacturer

PHT312-RO

  • Type | Passive probes | Temperature-resistant probes
  • Input withstand voltage | 400V(AC rms) |
  • Frequency bandwidth | 350MHz |
  • Attenuation |10:1|
  • Applications | Thermostatic chamber measurement |
  • Manufacturer | PMK |

A probe that can be used with guaranteed performance in high temperature and high humidity such as thermostatic chambers

400MHz 400V 2m 155℃
  • Model: PHT Series (manufactured by PMK)/Passive single end probe
  • Frequency bandwidth: DC~350MHz
  • Input withstand voltage:400Vrms(No Category),1,650V (transient overvoltage)
  • Operating temperature and humidity:-55ºC~+155ºC,Maximum relative humidity: 98%

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PKT Series

  • Type | Passive probes |
  • Input withstand voltage | 400V(AC rms) |
  • Frequency bandwidth | 350MHz, 300MHz | 400MHz | 500MHz |
  • Attenuation | 10:1 | 100:1 |
  • Applications | System equipment (BNC-BNC connection) |
  • Manufacturer | PMK |

Coaxial (cable divider) probe with BNC shape at the tip of the input (20 types)

500MHz 400V 1.2m
  • Model: PKT Series (manufactured by PMK)/Passive single end probe
  • Frequency bandwidth: DC~300MHz, 350MHz, 400MHz, 500MHz
  • Input withstand voltage : 400Vrms(No Category)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

Bumblebee

  • Type | High voltage differential probe |
  • Input withstand voltage | 2000V(AC rms) |
  • Frequency bandwidth | 400MHz |
  • Attenuation | 50:1 | 100:1 | 250:1 | 500:1|
  • Applications | High voltage measurement (floating) | Inverter/power measurement probes |
  • Manufacturer | PMK |

Supports measurements based on other than 0V. Ideal for measuring the actual operating waveform of inverter switching devices (broadband/high CMRR characteristics)

400MHz 2kV 2m〜
  • Model: Bumblebee (manufactured by PMK)/Active/Differential probe
  • Frequency bandwidth: DC~400MHz
  • Input withstand voltage: 2,000V (DC + ACpk differential input), 6,000V (transient overvoltage)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:* A probe control box is always required.

SS-320

  • Type | High voltage differential probe |
  • Input withstand voltage | 1400V(DC+ACpk) |
  • Frequency bandwidth| 100MHz |
  • Attenuation | 50:1 | 500:1 |
  • Applications | High voltage measurement (floating) | Inverter/power measurement probes |
  • Manufacturer | IWATSU |

Supports measurements based on other than 0V. Ideal for measuring the actual operating waveform of inverter switching devices from commercial power supplies

100MHz 1.4kV 2m
  • Model: SS-320/Active/Differential probe
  • Frequency bandwidth: DC~100MHz
  • Input withstand voltage: 1,400V (DC + ACpk differential input), 1,400V (DC + ACpk in-phase input)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:Oscilloscope with power supply for active probes, ViewGo II power supply option DS-579, or external power supply PS-25 is required.

IE-1165

  • Type | High voltage differential probes (depends on connection probe) | Differential amplifiers |
  • Input withstand voltage | ±18V (measurable voltage) |
  • Frequency bandwidth | 200MHz |
  • Attenuation |10:1|
  • Applications | High voltage measurement (floating) | Inverter/power measurement probes (separate pair probe) |
  • Manufacturer | IWATSU |

Passive single-end differential pair probe combination with a differential probe that supports various voltage inputs

200MHz
  • Model: IE-1165/Active/Differential amplifier
  • Input
    Frequency bandwidth: DC~200MHz
    Input withstand voltage: ±250V(MAX)
    Attenuation: 10:1
  • Output
    Output potential: ±2V (50Ω)
    Output resistance: 50Ω±2V
    Attenuation: 10:1

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:Driven by AC adapter or battery box

Sonic Series

  • Type | High bandwidth active probe |
  • Input withstand voltage | ±8V (measurable voltage) |
  • Frequency bandwidth| 4GHz |
  • Attenuation |10:1|
  • Applications | Crystal measurement probes | High frequency digital circuits |
  • Manufacturer | PMK |

An FET input probe that can measure high-frequency signals in high quality with a low input capacitance C (0.6pF) of the probe (2 types)

4GHz ±8V 1.3m
  • Model: SONIC Series (manufactured by PMK)/Active single end probe
  • Frequency bandwidth: DC~4GHz
  • Input withstand voltage: ±8V (measurable voltage range)/ 20V (MAX)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:• Separate probe cooler box (PS-02, etc.) is required.
    • Specify the output connector (BNC/SMA) to be connected to the measuring device.

TETRIS Series

  • Type | High bandwidth active probe |
  • Input withstand voltage | ±8V (measurable voltage) |
  • Frequency bandwidth | 1, 1.5GHz | 2.5GHz |
  • Attenuation | 10:1 |
  • Applications | Crystal measurement probes | High frequency digital circuits |
  • Manufacturer | PMK |

An FET input probe that can measure high-frequency signals in high quality with a low input capacitance C (0.9pF) of the probe (3 types)

2.5GHz ±8V 1.3m
  • Model: TETRIS Series (manufactured by PMK)/Active single end probe
  • Frequency bandwidth: DC~1GHz, 1.5GHz, 2.5GHz
  • Input withstand voltage: ±8V (measurable voltage range)/ ±20V (MAX)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

HV-P Series

  • Type | Passive probes | High voltage passive probes |
  • Input withstand voltage | 30kV(DC) | 60kV(DC) |
  • Frequency bandwidth | 50MHz |
  • Attenuation | 1000:1 | 2000:1 |
  • Applications | High voltage measurement (GND standard) |
  • Manufacturer | IWATSU |

Probes with excellent waveform quality for high voltage measurement of up to 60kV and 30kV (2 types)

50MHz 60kV 3m〜
  • Model: HV-P Series/Passive single end probe
  • Frequency bandwidth: DC~50MHz
  • Input withstand voltage: 30kV (DC+ACpk) / 40kV (Pulse), 60kV (DC+ACpk) / 80kV (Pulse)
  • Standard price: From 360,000 yen (excluding tax)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PHV1000 Series

  • Type | Passive probes | High voltage passive probes |
  • Input withstand voltage | 2kVpk(Pulse) |
  • Frequency bandwidth | 120MHz | 250MHz | 400MHz |
  • Attenuation | 100:1 |
  • Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
  • Manufacturer | PMK |

Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 1kV (CAT II), 2kVpeak (No Category) probes (12 types)

400MHz 2kV 2m〜
  • Model: PHV1000 Series (manufactured by PMK), Passive single end probe
  • Frequency bandwidth: DC~120MHz, 250MHz, 400MHz
  • Input withstand voltage: 1kV (CAT II), 2kVpeak (No Category)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PHV (S) 2000 Series

  • Type | Passive probes | High voltage passive probes |
  • Input withstand voltage | 4kVpk(Pulse) |
  • Frequency bandwidth | 120MHz | 250MHz | 400MHz |
  • Attenuation | 100:1 | 1000:1 |
  • Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
  • Manufacturer | PMK |

Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 1kV (CAT II), 4kVpeak (No Category) probes (24 types)

400MHz 4kV 2m〜
  • Model: PHV2000/PHVS2000 Series (manufactured by PMK), Passive single end probe
  • Frequency bandwidth: DC~120MHz, 250MHz, 400MHz
  • Input withstand voltage: 1kV (CAT II), 4kVpeak (No Category)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1