Choose by type, application, or function

Select by Type

Select by Input withstand voltage

Select by Frequency bandwidth

Select by Attenuation

Select by Application

Select by Manufacturer

FF-1500

  • Type| Isolated Probe |
  • Input withstand voltage| ±1V, ±10V, ±25V | ±50V | ±250V, ±500V | ±1kV, ±2.5kV |
  • Frequency bandwidth| 1.5GHz |
  • Attenuation| 1:1 | 10:1 | 25:1 | 50:1 | 250:1 | 500:1 | 1000:1 | 2500:1 |
  • Applications| High voltage measurement (floating) | Inverter/power measurement probes |
  • Manufacturer| PMK |

Optical isolation probe with wide bandwidth, high voltage, and high CMRR. Ideal for measuring the actual operating waveforms of switching devices in inverter.


1.5GHz
1V, 10V, 25V, 50V, 250V, 500V, 1kV, 2.5kV
2m
  • Model: FF-1500 (manufactured by PMK) / Active / Optically isolated probe
  • Frequency bandwidth: DC~1.5GHz
  • Input withstand voltage: ±1V, ±10V, ±25V, ±50V, ±250V, ±500V, ±1kV, ±2.5kV (DC+ACpk Defferential input), 60kV (Common mode input)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PHT312-RO

  • Type | Passive probes | Temperature-resistant probes
  • Input withstand voltage | 400V(AC rms) |
  • Frequency bandwidth | 350MHz |
  • Attenuation |10:1|
  • Applications | Thermostatic chamber measurement |
  • Manufacturer | PMK |

A probe that can be used with guaranteed performance in high temperature and high humidity such as thermostatic chambers

400MHz 400V 2m 155℃
  • Model: PHT Series (manufactured by PMK)/Passive single end probe
  • Frequency bandwidth: DC~350MHz
  • Input withstand voltage:400Vrms(No Category),1,650V (transient overvoltage)
  • Operating temperature and humidity:-55ºC~+155ºC,Maximum relative humidity: 98%

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PKT Series

  • Type | Passive probes |
  • Input withstand voltage | 400V(AC rms) |
  • Frequency bandwidth | 350MHz, 300MHz | 400MHz | 500MHz |
  • Attenuation | 10:1 | 100:1 |
  • Applications | System equipment (BNC-BNC connection) |
  • Manufacturer | PMK |

Coaxial (cable divider) probe with BNC shape at the tip of the input (20 types)

500MHz 400V 1.2m
  • Model: PKT Series (manufactured by PMK)/Passive single end probe
  • Frequency bandwidth: DC~300MHz, 350MHz, 400MHz, 500MHz
  • Input withstand voltage : 400Vrms(No Category)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

Bumblebee

  • Type | High voltage differential probe |
  • Input withstand voltage | 2000V(AC rms) |
  • Frequency bandwidth | 400MHz |
  • Attenuation | 50:1 | 100:1 | 250:1 | 500:1|
  • Applications | High voltage measurement (floating) | Inverter/power measurement probes |
  • Manufacturer | PMK |

Supports measurements based on other than 0V. Ideal for measuring the actual operating waveform of inverter switching devices (broadband/high CMRR characteristics)

400MHz 2kV 2m〜
  • Model: Bumblebee (manufactured by PMK)/Active/Differential probe
  • Frequency bandwidth: DC~400MHz
  • Input withstand voltage: 2,000V (DC + ACpk differential input), 6,000V (transient overvoltage)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:* A probe control box is always required.

SS-320

  • Type | High voltage differential probe |
  • Input withstand voltage | 1400V(DC+ACpk) |
  • Frequency bandwidth| 100MHz |
  • Attenuation | 50:1 | 500:1 |
  • Applications | High voltage measurement (floating) | Inverter/power measurement probes |
  • Manufacturer | IWATSU |

Supports measurements based on other than 0V. Ideal for measuring the actual operating waveform of inverter switching devices from commercial power supplies

100MHz 1.4kV 2m
  • Model: SS-320/Active/Differential probe
  • Frequency bandwidth: DC~100MHz
  • Input withstand voltage: 1,400V (DC + ACpk differential input), 1,400V (DC + ACpk in-phase input)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:Oscilloscope with power supply for active probes, ViewGo II power supply option DS-579, or external power supply PS-25 is required.

IE-1165

  • Type | High voltage differential probes (depends on connection probe) | Differential amplifiers |
  • Input withstand voltage | ±18V (measurable voltage) |
  • Frequency bandwidth | 200MHz |
  • Attenuation |10:1|
  • Applications | High voltage measurement (floating) | Inverter/power measurement probes (separate pair probe) |
  • Manufacturer | IWATSU |

Passive single-end differential pair probe combination with a differential probe that supports various voltage inputs

200MHz
  • Model: IE-1165/Active/Differential amplifier
  • Input
    Frequency bandwidth: DC~200MHz
    Input withstand voltage: ±250V(MAX)
    Attenuation: 10:1
  • Output
    Output potential: ±2V (50Ω)
    Output resistance: 50Ω±2V
    Attenuation: 10:1

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:Driven by AC adapter or battery box

Sonic Series

  • Type | High bandwidth active probe |
  • Input withstand voltage | ±8V (measurable voltage) |
  • Frequency bandwidth| 4GHz |
  • Attenuation |10:1|
  • Applications | Crystal measurement probes | High frequency digital circuits |
  • Manufacturer | PMK |

An FET input probe that can measure high-frequency signals in high quality with a low input capacitance C (0.6pF) of the probe (2 types)

4GHz ±8V 1.3m
  • Model: SONIC Series (manufactured by PMK)/Active single end probe
  • Frequency bandwidth: DC~4GHz
  • Input withstand voltage: ±8V (measurable voltage range)/ 20V (MAX)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:• Separate probe cooler box (PS-02, etc.) is required.
    • Specify the output connector (BNC/SMA) to be connected to the measuring device.

TETRIS Series

  • Type | High bandwidth active probe |
  • Input withstand voltage | ±8V (measurable voltage) |
  • Frequency bandwidth | 1, 1.5GHz | 2.5GHz |
  • Attenuation | 10:1 |
  • Applications | Crystal measurement probes | High frequency digital circuits |
  • Manufacturer | PMK |

An FET input probe that can measure high-frequency signals in high quality with a low input capacitance C (0.9pF) of the probe (3 types)

2.5GHz ±8V 1.3m
  • Model: TETRIS Series (manufactured by PMK)/Active single end probe
  • Frequency bandwidth: DC~1GHz, 1.5GHz, 2.5GHz
  • Input withstand voltage: ±8V (measurable voltage range)/ ±20V (MAX)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

HV-P Series

  • Type | Passive probes | High voltage passive probes |
  • Input withstand voltage | 30kV(DC) | 60kV(DC) |
  • Frequency bandwidth | 50MHz |
  • Attenuation | 1000:1 | 2000:1 |
  • Applications | High voltage measurement (GND standard) |
  • Manufacturer | IWATSU |

Probes with excellent waveform quality for high voltage measurement of up to 60kV and 30kV (2 types)

50MHz 60kV 3m〜
  • Model: HV-P Series/Passive single end probe
  • Frequency bandwidth: DC~50MHz
  • Input withstand voltage: 30kV (DC+ACpk) / 40kV (Pulse), 60kV (DC+ACpk) / 80kV (Pulse)
  • Standard price: From 360,000 yen (excluding tax)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PHV1000 Series

  • Type | Passive probes | High voltage passive probes |
  • Input withstand voltage | 2kVpk(Pulse) |
  • Frequency bandwidth | 120MHz | 250MHz | 400MHz |
  • Attenuation | 100:1 |
  • Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
  • Manufacturer | PMK |

Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 1kV (CAT II), 2kVpeak (No Category) probes (12 types)

400MHz 2kV 2m〜
  • Model: PHV1000 Series (manufactured by PMK), Passive single end probe
  • Frequency bandwidth: DC~120MHz, 250MHz, 400MHz
  • Input withstand voltage: 1kV (CAT II), 2kVpeak (No Category)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1