Choose by type, application, or function

Select by Type

Select by Input withstand voltage

Select by Frequency bandwidth

Select by Attenuation

Select by Application

Select by Manufacturer

PHV (S) 2000 Series

  • Type | Passive probes | High voltage passive probes |
  • Input withstand voltage | 4kVpk(Pulse) |
  • Frequency bandwidth | 120MHz | 250MHz | 400MHz |
  • Attenuation | 100:1 | 1000:1 |
  • Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
  • Manufacturer | PMK |

Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 1kV (CAT II), 4kVpeak (No Category) probes (24 types)

400MHz 4kV 2m〜
  • Model: PHV2000/PHVS2000 Series (manufactured by PMK), Passive single end probe
  • Frequency bandwidth: DC~120MHz, 250MHz, 400MHz
  • Input withstand voltage: 1kV (CAT II), 4kVpeak (No Category)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PHV (S) 66x Series

  • Type | Passive probes | High voltage passive probes |
  • Input withstand voltage | 6kVpk(Pulse) |
  • Frequency bandwidth | 80MHz | 120, 175MHz | 250MHz | 400MHz |
  • Attenuation | 100:1 | 1000:1 |
  • Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
  • Manufacturer | PMK |

Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 2.8krms, 4kV (DC + ACpk), 6kVpk probes (15 types)

400MHz 6kV 1.2m〜
  • Model: PHV66x/PHVS66x Series (manufactured by PMK), Passive single end probe
  • Frequency bandwidth:DC~175MHz, 250MHz, 300MHz, 400MHz
  • Input withstand voltage: [PHV66x] 2.8kVrms, 4kV (DC+ACpk), 6kV (pulse) [PHVS66x] 2.8kVrms, 4kV (DC+ACpk), 6kV (pulse)* rms is AC 50/60Hz sine wave, pulse is a pulse waveform less than or equal to 1/10 of the reference period

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

SS Series

  • Type | Passive probes |
  • Input withstand voltage | 500V(DC+ACpk) | 600V(DC+ACpk) |
  • Frequency bandwidth| 6, 60MHz | 100M, 200MHz | 500MHz |
  • Attenuation ratio | 1: 1 | 10: 1 |
  • Applications | General purpose probes |
  • Manufacturer | IWATSU |

Our recommended standard probe for oscilloscopes (attenuation ratio: 1: 1, 10: 1) (4 types)

500MHz 600V 1.1m〜
  • Model: SS Series/Passive single end probe
  • Frequency bandwidth: [1:1] DC~6MHz [10:1] DC~60MHz, 100MHz, 200MHz, 500MHz
  • Input withstand voltage: [1: 1] 500V (DC + ACpk) * Limited to the input withstand voltage of the oscilloscope. [10:1] 600V(DC+ACpk)
  • Standard price: From 8,800 yen (8,000 yen excluding tax)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PMM Series

  • Type | Passive probes |
  • Input withstand voltage | 400V(AC rms) |
  • Frequency bandwidth | 175MHz | 250MHz | 380MHz | 500MHz |
  • Attenuation |10:1 |
  • Applications | General purpose probes |
  • Manufacturer | PMK |

Ideal for oscilloscopes with a wide range of bandwidths up to 500MHz and compact size (12 types)

300MHz 400V 1.2m〜
  • Model: PMM Series (manufactured by PMK)/Passive single end probe
  • Frequency bandwidth: DC~175MHz, 250MHz, 380MHz, 500MHz
  • Input withstand voltage: 300Vrms (CAT II)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

SMP Series

  • Type | Passive probes |
  • Input withstand voltage
  • Frequency bandwidth | 35, 50MHz | 250MHz | 500MHz |
  • Attenuation | 1:1 | 2:1 |5:1 | 10:1 |
  • Applications | General purpose probes | Crystal measurement probes | High frequency digital circuits |
  • Manufacturer | PMK |

A thin passive probe that is capable of contacting adjacent 2.54mm pitch pins in parallel. (4 types)

500MHz 30V 1.3m〜
  • Model: SMP011, SMP021, SMP051, SMP101 (manufactured by PMK)/Passive thin end probe
  • Frequency bandwidth : [1:1] DC~35MHz [2:1] DC~50MHz [5:1] DC~250MHz [10:1] DC~500MHz
  • Input withstand voltage: 30Vrms

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

PML71x, 72x Series

  • Type | Passive probes |
  • Input withstand voltage | 30V(AC rms) | 60V(DC) | 400V(AC rms) |
  • Frequency bandwidth | 38MHz | 250MHz | 350MHz | 500MHz |
  • Attenuation | 1:1 | 10:1 | 20:1 |
  • Applications | Crystal measurement probes | High frequency digital circuits |
  • Manufacturer | PMK |

A thin passive probe that is capable of contacting adjacent 2.54mm pitch pins in parallel. (4 types)

500MHz 400V 1.2m〜
  • Model: PML211, 311, 701, 71x, 721 Series (manufactured by PMK)/Passive thin end probe
  • Frequency bandwidth: [1:1] DC~38MHz [10:1] DC~200MHz, 250MHz, 350MHz, 500MHz [20:1] DC~500MHz
  • Input withstand voltage: [1:1] 30Vrms, 60VDC [10:1] 300V (CAT II) [20:1] 300V (CAT II)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1
  • Remarks:The cable length can be changed (custom order).

PML75x, 79x Series

  • Type | Passive probes |
  • Input withstand voltage | 12, 30V(DC) |
  • Frequency bandwidth | 1.5GHz |
  • Attenuation | 10:1 | 100:1 |
  • Applications | Crystal measurement probes | High frequency digital circuits |
  • Manufacturer | PMK |

While achieving low input impedance (500Ω, 5kΩ), it is ideal for high-speed digital signal measurements of 50Ω systems because of the low input capacitance (2pF, 2.6pF) (4 types)

1.5GHz 30V 1.3m〜
  • Model: PML75x, 79x Series (manufactured by PMK)/Passive thin end probe
  • Frequency bandwidth:DC~1.5GHz
  • Input withstand voltage: [10:1] 12V (DC+ACpk) [100:1] 30V (DC+ACpk)

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1

SE-6000 Series

  • Type | Isolation Probe |
  • Input withstand voltage | 400Vpk [differential, depends on probe used] | 1kVpk [in phase] |
  • Frequency bandwidth |30MHz |
  • Attenuation
  • Applications | Cable length extension (up to 200m) | High voltage measurement (floating) |
  • Manufacturer | IWATSU |

Ideal when you want to electrically isolate from the object to be measured. Ideal when you want to take measurements at a distance from the object to be measured to reduce the impact of noise

30MHz 〜200m
  • Model: SE-6000 Series/Active probe
  • Frequency bandwidth : DC~30MHz
  • Input withstand voltage: Depends on probe used in combination with SE-6000

Attenuation

1:1 2:1 5:1 10:1 20:1 50:1 100:1 250:1 500:1 1000:1 2000:1 10000:1