Choose by type, application, or function
Select by Type
Select by Input withstand voltage
Select by Frequency bandwidth
Select by Attenuation
Select by Application
Select by Manufacturer
Probe for inverter/power supply measurement
FF-1500

- Type| Isolated Probe |
- Input withstand voltage| ±1V, ±10V, ±25V | ±50V | ±250V, ±500V | ±1kV, ±2.5kV |
- Frequency bandwidth| 1.5GHz |
- Attenuation| 1:1 | 10:1 | 25:1 | 50:1 | 250:1 | 500:1 | 1000:1 | 2500:1 |
- Applications| High voltage measurement (floating) | Inverter/power measurement probes |
- Manufacturer| PMK |
Optical isolation probe with wide bandwidth, high voltage, and high CMRR. Ideal for measuring the actual operating waveforms of switching devices in inverter.
1.5GHz 1V, 10V, 25V, 50V, 250V, 500V, 1kV, 2.5kV
2m
- Model: FF-1500 (manufactured by PMK) / Active / Optically isolated probe
- Frequency bandwidth: DC~1.5GHz
- Input withstand voltage: ±1V, ±10V, ±25V, ±50V, ±250V, ±500V, ±1kV, ±2.5kV (DC+ACpk Defferential input), 60kV (Common mode input)
Attenuation:
Bumblebee

- Type | High voltage differential probe |
- Input withstand voltage | 2000V(AC rms) |
- Frequency bandwidth | 400MHz |
- Attenuation | 50:1 | 100:1 | 250:1 | 500:1|
- Applications | High voltage measurement (floating) | Inverter/power measurement probes |
- Manufacturer | PMK |
Supports measurements based on other than 0V. Ideal for measuring the actual operating waveform of inverter switching devices (broadband/high CMRR characteristics)
- Model: Bumblebee (manufactured by PMK)/Active/Differential probe
- Frequency bandwidth: DC~400MHz
- Input withstand voltage: 2,000V (DC + ACpk differential input), 6,000V (transient overvoltage)
Attenuation:
- Remarks:* A probe control box is always required.
SS-320

- Type | High voltage differential probe |
- Input withstand voltage | 1400V(DC+ACpk) |
- Frequency bandwidth| 100MHz |
- Attenuation | 50:1 | 500:1 |
- Applications | High voltage measurement (floating) | Inverter/power measurement probes |
- Manufacturer | IWATSU |
Supports measurements based on other than 0V. Ideal for measuring the actual operating waveform of inverter switching devices from commercial power supplies
- Model: SS-320/Active/Differential probe
- Frequency bandwidth: DC~100MHz
- Input withstand voltage: 1,400V (DC + ACpk differential input), 1,400V (DC + ACpk in-phase input)
Attenuation:
- Remarks:Oscilloscope with power supply for active probes, ViewGo II power supply option DS-579, or external power supply PS-25 is required.
IE-1165 Discontinued

- Type | High voltage differential probes (depends on connection probe) | Differential amplifiers |
- Input withstand voltage | ±18V (measurable voltage) |
- Frequency bandwidth | 200MHz |
- Attenuation |10:1|
- Applications | High voltage measurement (floating) | Inverter/power measurement probes (separate pair probe) |
- Manufacturer | IWATSU |
Passive single-end differential pair probe combination with a differential probe that supports various voltage inputs
- Model: IE-1165/Active/Differential amplifier
- Input
Frequency bandwidth: DC~200MHz
Input withstand voltage: ±250V(MAX)
Attenuation: 10:1 - Output
Output potential: ±2V (50Ω)
Output resistance: 50Ω±2V
Attenuation: 10:1
Attenuation:
- Remarks:Driven by AC adapter or battery box
PHV1000 Series

- Type | Passive probes | High voltage passive probes |
- Input withstand voltage | 2kVpk(Pulse) |
- Frequency bandwidth | 120MHz | 250MHz | 400MHz |
- Attenuation | 100:1 |
- Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
- Manufacturer | PMK |
Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 1kV (CAT II), 2kVpeak (No Category) probes (12 types)
- Model: PHV1000 Series (manufactured by PMK), Passive single end probe
- Frequency bandwidth: DC~120MHz, 250MHz, 400MHz
- Input withstand voltage: 1kV (CAT II), 2kVpeak (No Category)
Attenuation:
PHV (S) 2000 Series

- Type | Passive probes | High voltage passive probes |
- Input withstand voltage | 4kVpk(Pulse) |
- Frequency bandwidth | 120MHz | 250MHz | 400MHz |
- Attenuation | 100:1 | 1000:1 |
- Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
- Manufacturer | PMK |
Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 1kV (CAT II), 4kVpeak (No Category) probes (24 types)
- Model: PHV2000/PHVS2000 Series (manufactured by PMK), Passive single end probe
- Frequency bandwidth: DC~120MHz, 250MHz, 400MHz
- Input withstand voltage: 1kV (CAT II), 4kVpeak (No Category)
Attenuation:
PHV (S) 66x Series

- Type | Passive probes | High voltage passive probes |
- Input withstand voltage | 6kVpk(Pulse) |
- Frequency bandwidth | 80MHz | 120, 175MHz | 250MHz | 400MHz |
- Attenuation | 100:1 | 1000:1 |
- Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
- Manufacturer | PMK |
Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 2.8krms, 4kV (DC + ACpk), 6kVpk probes (15 types)
- Model: PHV66x/PHVS66x Series (manufactured by PMK), Passive single end probe
- Frequency bandwidth:DC~175MHz, 250MHz, 300MHz, 400MHz
- Input withstand voltage: [PHV66x] 2.8kVrms, 4kV (DC+ACpk), 6kV (pulse) [PHVS66x] 2.8kVrms, 4kV (DC+ACpk), 6kV (pulse)* rms is AC 50/60Hz sine wave, pulse is a pulse waveform less than or equal to 1/10 of the reference period
Attenuation: