Choose by type, application, or function
Select by Type
Select by Input withstand voltage
Select by Frequency bandwidth
Select by Attenuation
Select by Application
Select by Manufacturer
x <100MHz
HV-P Series

- Type | Passive probes | High voltage passive probes |
- Input withstand voltage | 30kV(DC) | 60kV(DC) |
- Frequency bandwidth | 50MHz |
- Attenuation | 1000:1 | 2000:1 |
- Applications | High voltage measurement (GND standard) |
- Manufacturer | IWATSU |
Probes with excellent waveform quality for high voltage measurement of up to 60kV and 30kV (2 types)
- Model:HV-P Series/Passive single end probe
- Frequency bandwidth:DC~50MHz
- Input withstand voltage:30kV (DC+ACpk) / 40kV (Pulse), 60kV (DC+ACpk) / 80kV (Pulse)
Attenuation:
PHV (S) 66x Series

- Type | Passive probes | High voltage passive probes |
- Input withstand voltage | 6kVpk(Pulse) |
- Frequency bandwidth | 80MHz | 120, 175MHz | 250MHz | 400MHz |
- Attenuation | 100:1 | 1000:1 |
- Applications | High voltage measurement (GND standard) | Inverter/power measurement probes |
- Manufacturer | PMK |
Can also be used for a wide range of general-purpose oscilloscopes!
High voltage 2.8krms, 4kV (DC + ACpk), 6kVpk probes (15 types)
- Model: PHV66x/PHVS66x Series (manufactured by PMK), Passive single end probe
- Frequency bandwidth:DC~175MHz, 250MHz, 300MHz, 400MHz
- Input withstand voltage: [PHV66x] 2.8kVrms, 4kV (DC+ACpk), 6kV (pulse) [PHVS66x] 2.8kVrms, 4kV (DC+ACpk), 6kV (pulse)* rms is AC 50/60Hz sine wave, pulse is a pulse waveform less than or equal to 1/10 of the reference period
Attenuation:
SS Series

- Type | Passive probes |
- Input withstand voltage | 500V(DC+ACpk) | 600V(DC+ACpk) |
- Frequency bandwidth| 6, 60MHz | 100M, 200MHz | 500MHz |
- Attenuation ratio | 1: 1 | 10: 1 |
- Applications | General purpose probes |
- Manufacturer | IWATSU |
Our recommended standard probe for oscilloscopes (attenuation ratio: 1: 1, 10: 1) (4 types)
- Model: SS Series/Passive single end probe
- Frequency bandwidth: [1:1] DC~6MHz [10:1] DC~60MHz, 100MHz, 200MHz, 500MHz
- Input withstand voltage: [1: 1] 500V (DC + ACpk) * Limited to the input withstand voltage of the oscilloscope. [10:1] 600V(DC+ACpk)
Attenuation:
SMP Series

- Type | Passive probes |
- Input withstand voltage
- Frequency bandwidth | 35, 50MHz | 250MHz | 500MHz |
- Attenuation | 1:1 | 2:1 |5:1 | 10:1 |
- Applications | General purpose probes | Crystal measurement probes | High frequency digital circuits |
- Manufacturer | PMK |
A thin passive probe that is capable of contacting adjacent 2.54mm pitch pins in parallel. (4 types)
- Model: SMP011, SMP021, SMP051, SMP101 (manufactured by PMK)/Passive thin end probe
- Frequency bandwidth : [1:1] DC~35MHz [2:1] DC~50MHz [5:1] DC~250MHz [10:1] DC~500MHz
- Input withstand voltage: 30Vrms
Attenuation:
PML71x, 72x Series

- Type | Passive probes |
- Input withstand voltage | 30V(AC rms) | 60V(DC) | 400V(AC rms) |
- Frequency bandwidth | 38MHz | 250MHz | 350MHz | 500MHz |
- Attenuation | 1:1 | 10:1 | 20:1 |
- Applications | Crystal measurement probes | High frequency digital circuits |
- Manufacturer | PMK |
A thin passive probe that is capable of contacting adjacent 2.54mm pitch pins in parallel. (4 types)
- Model: PML211, 311, 701, 71x, 721 Series (manufactured by PMK)/Passive thin end probe
- Frequency bandwidth: [1:1] DC~38MHz [10:1] DC~200MHz, 250MHz, 350MHz, 500MHz [20:1] DC~500MHz
- Input withstand voltage: [1:1] 30Vrms, 60VDC [10:1] 300V (CAT II) [20:1] 300V (CAT II)
Attenuation:
- Remarks:The cable length can be changed (custom order).
SE-6000 Series

- Type | Isolation Probe |
- Input withstand voltage | 400Vpk [differential, depends on probe used] | 1kVpk [in phase] |
- Frequency bandwidth |30MHz |
- Attenuation
- Applications | Cable length extension (up to 200m) | High voltage measurement (floating) |
- Manufacturer | IWATSU |
Ideal when you want to electrically isolate from the object to be measured. Ideal when you want to take measurements at a distance from the object to be measured to reduce the impact of noise
- Model: SE-6000 Series/Active probe
- Frequency bandwidth : DC~30MHz
- Input withstand voltage: Depends on probe used in combination with SE-6000
Attenuation:
- Remarks:The attenuation ratio depends on the probe used in combination