Digital Oscilloscope "ViewGo II" DS-5600A Series Options

Dedicated Options

DS-576

GPIB interface

DS-576/DS-578


DS-577

AUX I/O option (CH1/CH2 output)
* If you implement the DS-577 option, the standard AuxOut terminal is deleted. Therefore, the functions of "Trigger output" and "Pass/Fail judgment output" output using the AuxOut terminal will not be available.

DS-577

Output terminal
AUXI/O1: Output CH1 input signal with offset voltage added
AUXI/O2: Output CH2 input signal with offset voltage added
Each CH output specifications
Output resistance: 50Ω±5 %
Offset: ±30mV (at 50 Ω termination)
Frequency characteristics: Maximum frequency bandwidth/2
(-3 dB, at 50Ω termination)
Output voltage sensitivity: 30 mV/div±10 %
(At 50Ω termination)


DS-578

AUX I/O option (CH1 output)
* If the DS-578 option is implemented, the position of the AuxOut terminal installed as standard will be changed.
The left side facing the rear side becomes the CH1 output, and the position of the AuxOut terminal is changed to the right side.

DS-576/DS-578

Output terminal
AUXI/O1: Output CH1 input signal with offset voltage added
Output Specifications

CH1 output

Output resistance: 50Ω±5 %
Offset: ±30mV (at 50 Ω termination)
Frequency characteristics: Maximum frequency bandwidth/2
(-3 dB, at 50Ω termination)
Output voltage sensitivity: 30 mV/div±10 %
(At 50Ω termination)


DS-579

Probe Power Options

DS-579

Number of output channels: 2
Maximum output power:

9 VAmax

* Use the 2CH so that the total current consumption does not exceed 750mA.

Offset

Output voltage adjustment function

* FET probe-only valid functions

From the Utilities menu of the ViewGo II Series unit, it can be set for each channel.
Compatible probes:

Current probe

SS-531 / SS-530 / SS-521 /

SS-520 / SS-570 / SS-560 /

SS-550 / SS-540

* The above probes require a power conversion cable SS-200-IW.

 

SS-270 / SS-260 / SS-250 /

SS-240A / SS-240

 

FET probes

SFP-5A / SFP-4A


High voltage differential probe
 SS-320



IE-1226 (Made-to-order)

The VGA Video OUT option
waveform screen can be output to an external display.
* After implementing IE-1226, DS-579 cannot be used.

 IE-1226 VGA options



Carrying bag

* Commercial product, multi-purpose bag

DS-5500 bag


Standard probe

SS-0130R

Frequency bandwidth:DC~200MHz
Input RC:10MΩ//12.5pF
Attenuation:10:1
Length:1.5m
Compatible models:
DS-551xA / DS-552xA / DS-541x / DS-542x / DS-561xA / DS-562xA / DS-541xA / DS-542xA / DS-561x / DS-562x

SS-0130R


SS-101R

(Discontinued)

Frequency bandwidth:DC~500MHz
Input RC:10MΩ//12pF
Attenuation:10:1
Length:1.2m
Compatible models:
DS-553xA / DS-555xA / DS-563x / DS-565x / DS-563xA / DS-565xA

SS-101R


SS-150R

(SS-101R successor probe)

Frequency bandwidth:DC~500MHz
Input RC:10 MΩ±2 %//12.5 pF±10%
Attenuation:10:1
Length:1.5m
Compatible models:
DS-553xA / DS-555xA / DS-563x / DS-565x / DS-563xA / DS-565xA

SS-101R


High voltage differential probe

SS-320

Frequency bandwidth:DC~100MHz
Attenuation:50:1, 500:1
Maximum differential operating voltage:±1400 V(DC + AC peak,
500:1
Full length:2m

SS-320


DS-579

Probe Power Options
Probes compatible with probe power units

for ViewGo II are available here.

DS-579


Probe Power SuppliesPS-25

Power supply for SFP-5A/4A/SS-320
Power output: ±12V (±5%, 120mA max) x 2ch
Offset signal output: ±1.6V
(in combination with SFP-5A/4A, offset adjustment of ±20V is possible)

PS-25


Active Probes

DS-579

Probe Power Options
Probes compatible with probe power units

for ViewGo II are available here.

DS-579


Probe Power Supply PS-25

Power supply for SFP-5A/4A/SS-320
Power output: ±12V (±5%, 120mA max) x 2ch
Offset signal output: ±1.6V
(in combination with SFP-5A/4A, offset adjustment of ±20V is possible)

PS-25


High Voltage Probes

PHV 1000-RO

Attenuation ratio… 100:1, Input RC… 50MΩ 7.5pF
Frequency band… 400MHz (for single probe)
Capacitance variable range… 10-50pF, Length… 2m

PHV1000


HV-P30A

DC to 50MHz, DC-30kV, pulse 40kV

HV-P30A


HV-P60A

DC to 50MHz, DC-60kV, pulse 80kV

HV-P60A


  • High-voltage probes should be selected after checking the derating characteristics.

Current probe

Rogowski-Coil Current Probe SS-28xA Series

Frequency band: fL to 30MHz
Maximum peak current: 3,000A
Sensor temperature range: -40°C to 125°C

Rogowski-Coil Current Probe


Rogowski-Coil Current Probe SS-29x Series

Frequency band: S-type -fL to 20MHz, L-type -fL to 10MHz
Maximum peak current: 12kA
Sensor temperature range :-40℃~125℃

Rogowski-Coil Current Probe


DS-579

Probe Power Options
Probes compatible with probe power units

for ViewGo II Series are available here.

DS-579


  • In the case of a single probe, a calibration certificate, traceability system figure, and inspection report will be charged separately.